Washington, Pennsylvania. Since 2011.

Two independent recorders on every test

A Barton 12 inch dual pin chart and a Crystal nVision digital logger run on the same test, on separate power and separate clocks. Most vendors run one instrument. When one is challenged, the other one has already answered, and the test does not get repeated on your cost code.

Close view of a dual pin chart recorder with both pens riding the chart

The short version

  • 2011

    Operating since

    Flagged for client confirmation

  • 30 min

    From three states

    Pittsburgh, West Virginia, Ohio

  • 720,000

    SCFH maximum rate

    To 8,900 psi

  • 6 mo

    Instrument recertification

    Every instrument, every interval

Washington sits in the Marcellus and Utica core, roughly thirty minutes from Pittsburgh and from both the West Virginia and Ohio borders.

WOSB, DOT, HAZMAT, Veriforce, NCCER, ISNetworld, ISTC

Why this shop

What is actually different here

  • Interior of a receiver barrel holding a returned pig and line debris

    Pigging lines that were never built to be pigged

    No launcher and no receiver is not a reason to skip the run. We fabricate a bell piece that fits over the opening and acts as a launcher.

    How the bell piece works
  • Dew point meter reading minus 77.9 degrees Fahrenheit after a nitrogen dry

    Verified dry, not claimed dry

    Nitrogen dried to a negative dew point and measured with a DeFelsko meter that reads to minus 100°F. Anyone can say the line is dry. We hand you the number.

    Dew point verification
  • Cryogenic nitrogen transport trailer coupled to its tractor

    Single source, no brokered links

    We own the nitrogen, the trailers, the pump trucks, the recorders, and the operators. Most competitors broker at least one link, usually the gas.

    What we own
  • Pumper unit working from a right of way beside a plant

    Sized for the contradiction

    720,000 SCFH and 8,900 psi in a unit that is 8 feet 2 inches wide and still fits down a lease road.

    Full specifications
  • Mobile testing unit and crew trucks staged at a processing plant

    Woman Owned Small Business

    Registered in SAM under NAICS 213112. A supplier diversity unlock at every prime carrying a target, with a capability statement built for procurement.

    Capability statement
  • Digital test gauge reading 2,194 psi on a remote stand

    We kept the analog deadweight

    Because certain standards still require one and will not take a digital substitute. It stays in the kit and stays on the recertification schedule.

    Instrumentation

Next step

Send the scope. You get a number back.